1 slords 1.1 # $Id: rockwell,v 1.2 1996/06/24 02:58:40 sam Rel $
2     #
3     # HylaFAX Facsimile Software
4     #
5     # Copyright (c) 1990-1996 Sam Leffler
6     # Copyright (c) 1991-1996 Silicon Graphics, Inc.
7     # HylaFAX is a trademark of Silicon Graphics, Inc.
8     #
9     # Permission to use, copy, modify, distribute, and sell this software and
10     # its documentation for any purpose is hereby granted without fee, provided
11     # that (i) the above copyright notices and this permission notice appear in
12     # all copies of the software and related documentation, and (ii) the names of
13     # Sam Leffler and Silicon Graphics may not be used in any advertising or
14     # publicity relating to the software without the specific, prior written
15     # permission of Sam Leffler and Silicon Graphics.
16     #
17     # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
18     # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
19     # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
20     #
21     # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
22     # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
23     # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
24     # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
25     # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
26     # OF THIS SOFTWARE.
27     #
28    
29     #
30     # Configuration for a Rockwell-based modem not otherwise handled by
31     # another prototype configuration file. This file assumes the modem
32     # is compatible with the Rc144AC, RC96AC or RC144DP.
33     #
34     # This configuration file sets up the modem to run at 38.4 with
35     # RTS/CTS flow control used by default. XON/XOFF is automatically
36     # enabled for fax recv. Beware of modems that also lock sending
37     # to 19.2; add ModemSendBeginCmd: "<19200>" if this is required.
38     # Also beware that the adaptive-answer facility, when supported,
39     # is often unreliable.
40     #
41     #
42     CountryCode: 1
43     AreaCode: 999
44     FAXNumber: +1.999.555.1212
45     LongDistancePrefix: 1
46     InternationalPrefix: 011
47     DialStringRules: "etc/dialrules.sf-ba"
48     ServerTracing: 1
49     SessionTracing: 11
50     RecvFileMode: 0600
51     LogFileMode: 0600
52     DeviceMode: 0600
53     RingsBeforeAnswer: 1
54     SpeakerVolume: off
55     GettyArgs: "-h %l %s"
56     LocalIdentifier: "Silent Valley Sys"
57     TagLineFont: etc/lutRS18.pcf
58     TagLineFormat: "From %%l|%c|Page %%p of %%t"
59     MaxRecvPages: 25
60     #
61     #
62     # Modem-related stuff: should reflect modem command interface
63     # and hardware connection/cabling (e.g. flow control).
64     #
65     ModemType: Class2 # use class 2 interface
66     ModemRate: 38400
67     ModemFlowControl: rtscts # default
68     #
69     ModemResetCmds: AT&F # what you want for a Supra
70     ModemNoFlowCmd: AT&K0 # disable flow control cmd
71     ModemHardFlowCmd: AT&K3 # hardware flow control cmd
72     ModemSoftFlowCmd: AT&K4 # software flow control cmd
73     ModemSetupDTRCmd: AT&D3 # DTR off causes modem to reset
74     #ModemSetupDTRCmd: AT&D2S25=1S38=0 # Dynalink 1414VE needs this
75     ModemSetupDCDCmd: AT&C1 # DCD follows carrier
76     ModemSetupAACmd: AT+FAA=1+FCLASS=0 # enable in current class
77     #
78     ModemSendFillOrder: LSB2MSB # as expected
79     ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
80     #
81     ModemAnswerFaxBeginCmd: "<19200><rts>" # modem switches on fax receive
82     #
83     # Caller ID configuration setup for Supra.
84     #
85     #QualifyCID: etc/cid # CID access control list file
86     #CIDNumber: "NMBR = " # pattern string for phone number info
87     #CIDName: "NAME = " # pattern string for identity info
88     Class2RecvDataTrigger: "\022" # character sent to modem to start recv